Books > Professional & Technical > Civil engineering, surveying & building > Building construction & materials > Fire protection & safety
|
Buy Now
Smoke Component Yields from Bench-scale Fire Tests - 1. Nfpa 269 / ASTM E 1678 (Paperback)
Loot Price: R407
Discovery Miles 4 070
|
|
Smoke Component Yields from Bench-scale Fire Tests - 1. Nfpa 269 / ASTM E 1678 (Paperback)
(sign in to rate)
Loot Price R407
Discovery Miles 4 070
Expected to ship within 10 - 15 working days
|
A standard procedure is needed for obtaining smoke toxic potency
data for use in fire hazard and risk analyses. Room fire testing of
finished products is impractical, directing attention to the use of
apparatus that can obtain the needed data quickly and at affordable
cost. This report examines the first of a series bench-scale fire
tests to produce data on the yields of toxic products in both
pre-flashover and post-flashover flaming fires. The apparatus is
the radiant furnace in NFPA 269 and ASTM E 1678. Test specimens
were cut from finished products that were also burned in room-scale
tests: a sofa made of upholstered cushions on a steel frame,
particleboard bookcases with a laminated finish, and household
electric power cable. Initially, the standard test procedure was
followed, with a variation to reduce the contribution to the
effluent of post- flaming pyrolysis. Subsequent variations in the
procedure included cutting the test specimen into small pieces and
performing the tests at a reduced oxygen volume fraction of 0.17.
The yields of CO2 CO, HCl, and HCN were determined. The yields of
other toxicants (NO, NO2, formaldehyde, and acrolein) were below
the detection limits, but volume fractions at the detection limits
were shown to be of limited toxicological importance relative to
the detected toxicants. In general, dicing the test specimen and
performing the tests at the reduced oxygen volume fraction had
little effect on the toxic gas yields, within the experimental
uncertainties. The exceptions were an increase in the CO yield for
diced specimens at reduced oxygen, a decrease in the HCN yield from
the intact sofa and cable specimens at reduced oxygen, and an
increase in the HCN yield from dicing the cable specimens. In none
of the procedure variations did the CO yield approach the value of
0.2 found in real-scale post flashover fire tests.
General
Is the information for this product incomplete, wrong or inappropriate?
Let us know about it.
Does this product have an incorrect or missing image?
Send us a new image.
Is this product missing categories?
Add more categories.
Review This Product
No reviews yet - be the first to create one!
|
|
Email address subscribed successfully.
A activation email has been sent to you.
Please click the link in that email to activate your subscription.