Groundwater polyaromatic hydrocarbon (PAH) concentrations
underneath a contaminated site were measured with gas
chromatography-mass spectrometry (GC-MS). As a form of soil
flushing is planned as an in situ treatment for some sectors at the
site, a cube of approximately 10 m was used to test the treatment.
To gain a deeper understanding of the contamination situation of
the test cube, a three dimensional visualisation of the pollutants
distribution in the cube was created. Total PAH measurements were
compared with eluate PAH measurements in two different
visualisations, showing that the contamination situation is
heterogeneous and complex, as the site contains PAH and hetero-PAH
contaminations which vary largely in their composition. The
contaminated groundwater of the in situ test plant was measured for
PAHs and hetero-PAHs with GC-MS. It was found that the hetero-PAH
composition of the groundwater changed significantly (p