0
Your cart

Your cart is empty

Books > Medicine > Other branches of medicine > Nuclear medicine

Buy Now

Basics of PET Imaging - Physics, Chemistry, and Regulations (Paperback, 2nd ed. 2010) Loot Price: R2,537
Discovery Miles 25 370
Basics of PET Imaging - Physics, Chemistry, and Regulations (Paperback, 2nd ed. 2010): Gopal B. Saha

Basics of PET Imaging - Physics, Chemistry, and Regulations (Paperback, 2nd ed. 2010)

Gopal B. Saha

 (sign in to rate)
Loot Price R2,537 Discovery Miles 25 370 | Repayment Terms: R238 pm x 12*

Bookmark and Share

Expected to ship within 10 - 15 working days

Sincethepublicationofthisbook in2005, thegrowthofpositron emission tomography(PET)andPET/CTmodalityhasbeenphenomenalwiththed- coveryofef?cientdetectorsandtheadditionofsophisticatedscannersand powerfulsoftware. Becauseofthevastadvancementandchangesintechn- ogy, andalso withgreatappreciationofthesuccess ofthe?rst edition, we thoughtasecondeditionofthebookwouldbeappropriate. Thebookisrevisedtoagainful?lltheneedsofnuclearmedicineprof- sionalssuchasphysicians, technologists, andresidents, alongwithstudents fortheirboardexaminationandtraining. Thecontentsofthebookhavebeen keptatthebasiclevelaswasinthe?rstedition. The organization of the book essentially has remained the same. Some chaptershavebeenrevisedvery extensively, while others haveonly minor changes. NochangehasbeenmadeinChap. 1asitisbasedonbasicphysics. Extensive revision has been made in Chaps. 2 and 3 to include up-to-date information on detectors, scanners, and data collection. Chapter 4 in the original edition has been divided into Chaps. 4 and 5 to allow for a se- ratechapteron"Storage,Display,andPACS. "Chapter6hasbeenupdated withnewinformationonNEMAstandardsonacceptancetestsofPETsc- ners. NewPETradionuclidesandthelistofcurrentavailablecyclotronshave beenaddedtoChap. 7. Chapter8includesasectiononCompoundingofPET Radiopharmaceuticals,inadditiontoseveralnewPETradiopharmaceuticals. NewregulationsconcerningtheuseofPETradiopharmaceuticals,thelice- ingofphysiciansandtechnologists,andtheaccreditationofPETfacilitiesto beeligibleforreimbursementforPETproceduresareallincludedinChap. 9. Chapter10hasbeenrevised,focusingontheissuesofcurrentreimbursement issuesforPETstudies. OnlyminorchangeshavebeenmadeinChaps. 11and 12toincludeup-to-dateinformation. Questionshavebeenaddedattheend ofeachchapter,asappropriate,tore?ectthechangesincontents. IthankmycolleaguesattheClevelandClinicFoundationfortheirsupport in manywaysand Mrs. DianeGrif?s for kindly typingand completingthe manuscriptontime. vii viii Preface IsincerelythankAndrewMoyer,editorofradiologyandnuclearmedicine, atSpringerforsupportandencouragement,andS. GeethalakshmiSrinivasan, ProjectManager,atSPiTechnologiesIndiaPvtLtdforexcellentproduction ofthebook. Cleveland,OH GopalB. Saha Contents 1. RadioactiveDecayandInteractionofRadiationwithMatter ...1 AtomicStructure ...1 RadioactiveDecay ...2 ?Decay ...2 ? ? Decay ...3 + Positron(?) Decay ...3 ElectronCapture ...3 IsomericTransition ...4 RadioactiveDecayEquations ...5 GeneralDecayEquations ...5 SuccessiveDecayEquations ...7 UnitsofRadioactivity ...9 UnitsofRadioactivityinSystemInternationale ...9 Calculations ...9 InteractionofRadiationwithMatter ...10 InteractionofChargedParticleswithMatter ...10 Interactionof?RadiationwithMatter ...12 Questions ...15 ReferencesandSuggestedReading ...17 2. PET ScanningSystems ...19 Background ...19 SolidScintillationDetectorsinPET ...20 PhotomultiplierTube ...24 PulseHeightAnalyzer ...25 ArrangementofDetectors ...25 PETScanners ...28 CoincidenceScintillationCameras ...29 PET/CTScanners ...30 SmallAnimalPETScanner ...33 MobilePETorPET/CT ...36 ix x Contents Questions ...38 ReferencesandSuggestedReading ...39 3. DataAcquisition and Corrections ...41 PETDataAcquisition ...41 TimeofFlightMethod ...46 Two-Dimensionalvs. Three-Dimensional DataAcquisition ...47 FactorsAffectingAcquiredPETData ...49 Normalization ...49 PhotonAttenuation ...50 AttenuationCorrectionMethods ...52 RandomCoincidences ...53 ScatterCoincidences ...55 CorrectionforScatterCoincidences ...56 DeadTime ...58 RadialElongation ...59 PET/CTDataAcquisition ...6 0 FactorsAffectingPET/CTData ...62 Questions ...67 ReferencesandSuggestedReading ...68 4. ImageReconstruction ...71 SimpleBackprojection ...71 FilteredBackprojection ...72 TheFourierMethod ...73 TypesofFilters ...75 IterativeReconstruction ...

General

Imprint: Springer-Verlag New York
Country of origin: United States
Release date: November 2014
First published: 2010
Authors: Gopal B. Saha
Dimensions: 235 x 155 x 15mm (L x W x T)
Format: Paperback
Pages: 241
Edition: 2nd ed. 2010
ISBN-13: 978-1-4899-8471-5
Categories: Books > Medicine > Other branches of medicine > Nuclear medicine
Books > Medicine > Other branches of medicine > Medical imaging > Radiology
LSN: 1-4899-8471-2
Barcode: 9781489984715

Is the information for this product incomplete, wrong or inappropriate? Let us know about it.

Does this product have an incorrect or missing image? Send us a new image.

Is this product missing categories? Add more categories.

Review This Product

No reviews yet - be the first to create one!

Partners